Key Factors When Installing PDUs in a Data Centre

Deploying PDUs within a data centre requires careful planning. Facilities teams must review equipment demand, rack layout, and electrical supply before installation starts. Proper planning supports safe power distribution and reduces the risk of overload.



Assessing Total Power Requirements



The first step is calculating total power requirements. Each device within the rack draws a specific amount of current. Technicians should calculate the combined load to ensure the selected PDU can support connected equipment. Using a unit with insufficient capacity may lead to circuit failure.



Selecting the Right Rack Configuration



Rack configuration directly affects PDU selection. Vertical PDUs offer multiple outlets without occupying equipment mounting space and are often installed along the rear of the cabinet. Horizontal PDUs fit within rack units and are used where vertical space is limited.



Input Power Type & Load Balancing



Input power type must be considered. Some PDUs are designed for single-phase supply, while others accommodate three-phase input. Three-phase PDUs enable power to be distributed across separate circuits, which helps balancing electrical load.



Outlet Compatibility



Outlet type should align with equipment plug requirements. Data centres often use a mix of C13 and C19 connectors depending on device demand. Selecting suitable outlet types ensures compatibility with connected hardware.



Structured Cable Management



Cable management is another key factor. PDUs should be installed in a way that supports organised routing of power leads. Clear routing minimises airflow obstruction and supports cooling efficiency.



Monitoring and Visibility



Monitoring features may also affect selection. Metered or intelligent PDUs enable facilities teams to track electrical usage. This visibility assists in identifying underused capacity and aids future expansion planning.



Redundancy and Business Continuity



Redundancy planning is essential in facilities that require continuous operation. Automatic transfer switch PDUs allow equipment to remain powered if the primary supply fails. Backup systems maintain business continuity during electrical interruptions.



Post-Installation Checks



Routine inspection should follow installation. Technicians should confirm secure mounting and check input connections. Ongoing testing maintains electrical safety across the data centre.



PDUs support reliable power distribution across IT infrastructure. Careful installation safeguards equipment and maintains operational stability within data centre environments.